The TLS-100 is a portable meter used to measure thermal conductivity and thermal resistivity of a variety of samples, including soil, rocks, concrete, and polymers.
Bitte geben Sie Ihre E-Mail-Adresse ein, um die Broschüre herunterzuladen.
The TLS-100 is a portable meter used to measure thermal conductivity and thermal resistivity of a variety of samples, including soil, rocks, concrete, and polymers. Tests can be performed with the push of a button and results displayed instantly. The second generation TLS-100 has many advancements, such as sensors which are auto-recognized, with corresponding testing parameters automatically loaded.
The Transient Line Source (TLS) meter follows ASTM D5334 and IEEE 442-2017. The sensor needle consists of a thin heating wire and temperature sensor sealed in a 150, 100 or 50 mm steel tube. The sensor is completely inserted into the sample to be tested. Heat is delivered to the sample using a constant current source (q) and the temperature rise is recorded over a defined period of time. The slope (a) from plot of temperature rise versus logarithm of time is used in the calculation of thermal conductivity (k). The higher the thermal conductivity of a sample, the lower the slope. For samples of low thermal conductivity, the slope will be higher.
Materialien | Soil, Rock, Concrete, & Polymers |
---|---|
Messfähigkeiten | Schüttgut-Eigenschaften |
Wärmeleitfähigkeit | 0,1 bis 5 W/m•K |
Wärmewiderstand | 0.2 to 10 m•K/W |
Messzeit | 3 Minuten |
Reproduzierbarkeit | ± 2% |
Genauigkeit | ± 5% |
Temperaturbereich | -40 bis 100°C |
Größte Stichprobengröße | Unbegrenzt |
Normen | 100 mm: ASTM D5334, and IEEE 442-1981; 150mm: ASTM D5334, IEEE 442-1981, and IEEE 442-2017 |
Each TLS-100 comes equipped with the standard 100 mm sensor for testing of soil, soft materials, polymers and easy to drill materials. The needle sensor is fully inserted into an isothermal sample and a measurement is made with the push of a button. After 180 seconds, results are displayed for thermal conductivity and thermal resistivity. Saved results can also be exported to a computer, via convenient utility software and USB connection.
Soil thermal Dryout Curves can be prepared by measuring the thermal conductivity of a sample at different moisture contents, as the sample dries from saturation. The typical drying approach involves heating the soil at an elevated temperature. The sample is removed, weighed, and measured for thermal conductivity at different time intervals, until it is fully dried.
Materialien | Böden, Pasten, Pulver und Feststoffe |
---|---|
Messfähigkeiten | Schüttgut-Eigenschaften |
Wärmeleitfähigkeit | 0,1 bis 5 W/m•K |
Wärmewiderstand | 0.2 to 10 m•K/W |
Messzeit | 3 Minuten |
Reproduzierbarkeit | ± 2% |
Genauigkeit | ± 5% |
Temperaturbereich | -40 bis 100°C |
Mindestgröße der Probe | 100 mm Länge, 50 mm Durchmesser |
Größte Stichprobengröße | Unbegrenzt |
Normen | ASTM D5334, IEEE 442-1981 |
The 50 mm sensor was designed for testing hard samples, like rock and concrete. Drilling the required 4 mm diameter x 50 mm hole in rigid samples is easy with the provided masonry drill bit. When testing hard samples, a thermal contact grease is used to enhance contact between the sensor and sample.
Materialien | Beton, Gestein und Polymere |
---|---|
Messfähigkeiten | Schüttgut-Eigenschaften |
Wärmeleitfähigkeit | 0,3 bis 5 W/m•K |
Wärmewiderstand | 0.2 to 3.3 m•K/W |
Messzeit | 3 Minuten |
Reproduzierbarkeit | ± 2% |
Genauigkeit | ± 5% |
Temperaturbereich | -40 bis 100°C |
Mindestgröße der Probe | 50 mm Länge, 50 mm Durchmesser |
Größte Stichprobengröße | Unbegrenzt |
Normen | Modified ASTM D5334 |
Materialien | Böden, Pasten, Pulver und Feststoffe |
---|---|
Messfähigkeiten | Schüttgut-Eigenschaften |
Wärmeleitfähigkeit | 0,1 bis 3 W/m•K |
Wärmewiderstand | 0.3 to 10 m•K/W |
Messzeit | 3 Minuten |
Reproduzierbarkeit | ± 2% |
Genauigkeit | ± 5% |
Temperaturbereich | -40 bis 100°C |
Mindestgröße der Probe | 150 mm Länge, 50 mm Durchmesser |
Größte Stichprobengröße | Unbegrenzt |
Normen | ASTM D5334, IEEE 442-2017 |
Materialien | Böden, Pasten, Pulver und Feststoffe |
---|---|
Messfähigkeiten | Schüttgut-Eigenschaften |
Wärmeleitfähigkeit | 0,1 bis 5 W/m•K |
Reproduzierbarkeit | ± 2% |
Genauigkeit | ±5% |
Thermische Diffusivität | 0,05 bis 1,5 mm²/s |
Genauigkeit | ± 10% |
Volumetrische spezifische Wärme | Bis zu 2,5 MJ/m³K |
Genauigkeit | ± 15% |
Temperaturbereich | -40 bis 100°C |
Mindestgröße der Probe | 100 mm Länge, 50 mm Durchmesser |
Größte Stichprobengröße | Unbegrenzt |
Normen | ASTM D5334 |
— Ruchita Jani, Postgraduate Researcher at TU Dublin
— Johan du Plessis, CEO at Tepeo
— Dr.-Ing. Steffen Trinks, Pedotec GmbH Berlin
Füllen Sie einfach das Formular aus und schicken Sie es ab. Eines unserer qualifizierten Teammitglieder wird sich mit Ihnen in Verbindung setzen und Ihnen ein auf Ihre Bedürfnisse zugeschnittenes Angebot unterbreiten.