HFM-25 Medidor de flujo de calor

The HFM-25 is a portable heat flow meter for the measurement of thermal resistance and thermal conductivity of small samples of insulation and construction materials.

El mejor para small samples of insulation and construction materials
HFM-25 heat flow meter
The Heat Flow Meter (HFM) 25 for the measurement of thermal resistance and thermal conductivity of small samples of insulation and construction materials. Offering the testing power of a full-size heat flow meter, optimized for small insulation samples and budget.

Características

HFM-25 features

The economic HFM-25 was designed to meet the growing need for steady-state testing of small samples of insulation for true thermal resistance and thermal conductivity.

Designed with simplicity in mind, a sample is positioned between the two heating – cooling plates. Plate contact is controlled manually, with variable pressure applied with the use of standard weights. Thickness is conveniently reported with included digital gauge. Testing on compressible samples is possible with included shims.

Ambient room temperature is automatically detected, users can choose from 5, 10, 15, and 20 °C delta ranges. One heat flux sensor is integrated into each plate and is used to monitor heat flux (Q/A), generated due to the difference in temperature (ΔT) between the top and bottom plate at regular intervals until steady-state heat flux is observed. The composite heat flux is then used to measure thermal resistance (R) and calculate thermal conductivity (λ) according to Fourier’s Law.

HFM-100 equation

Especificación

Conductividad Térmica

0,01 a 0,3 W/m•K

Directions

A través del espesor

Precisión

3%

Reproducibilidad

1%

Temperatura

Delta 5°C, 10°C, 15°C and 20°C at ambient temperature

Type of Sensors

Flux Sensors (x2) with surface thermocouples

Tamaño mínimo de muestra

50 x 50 x 2 mm

Tamaño máximo de muestra

25.4 mm

Maximum Sample (LxW)

Illimitado

Estándar

*ASTM C518, C1784, ISO 8301, JIS A1412, and EN 12664

* Applies for materials below 0.1 W/mK

Aplicaciones

NIST 1450d high-density fibrous glass board

Location Testing for Homogeneity

The homogeneity of NIST 1450d high-density fibrous glass board was measured with the HFM-25. Designed to test small samples or locations of 25 mm x 25 mm. The open concept sample clamping allows testing of large samples.

The four corners of the board were measured to analyze the homogeneity of sample. The % RSD from location to location was less than 1%, confirming the homogeneity

Aerogel Blanket

Aerogel Blanket

Aerogel blanket sample (50 x 50 x 9.58 mm) was selected to test by the HFM-25. Thermal conductivity of 0.014 W/m•K was measured at 23°C, which is within 3% of the manufacturer’s specification (measured by GHP – ASTM C177).
NIST SRM 1450d

NIST SRM 1450d

A sample of NIST SRM 1450d was measured for thermal conductivity for accuracy. The certified thermal conductivity for the NIST piece at 25°C is 0.0329 W/m•K. The measured thermal conductivity was 0.0330 W/m•K, which is within 1% of the certified value.

Heat Flow Meter (HFM) Models Comparison


HFM-100

HFM-25

Modelos

HFM-100

HFM-50

HFM-25

Materiales

Insulation, Solids, Construction Materials

Insulation, Solids, Construction Materials

Insulation, Textiles

Type of Sensors

Flux Sensors (x2)

Flux Sensors (x2)

Flux Sensors (x2)

Aplicaciones

Pruebas generales

Pruebas generales

Small Insulation

Direction

Through-thickness

Through-thickness

Through-thickness

Rango de conductividad térmica

0.002 to 0.5 W/m•K

0.002 to 0.5 W/m•K

0,01 a 0,3 W/m•K

Calor Específico

Optional

Optional

N/A

High Thermal Conductivity Kit

Up to 2.5 W/m•K

Up to 2.5 W/m•K

N/A

Tiempo de medición

30 to 40 minutes

30 to 40 minutes

20 minutes

Reproducibilidad

± 0.5 to 1%

± 0.5 to 1%

1%

Precisión

± 1 to 2%*

± 1 to 2%*

3%

Plate Temperature Range

-20 to 70 °C

-20 to 70 °C†

10 a 40 °C

Smallest Sample Size

250 x 250 x 5

150 x 150 x 5

50 x 50 x 2

Tamaño máximo de muestra

300 x 300 x 100

200 x 200 x 50

300 x 300 x 25

Normas

ASTM C518, C1784, ISO 8301, JIS A1412, EN 12667, and EN 12664

*Performance verified with NIST 1450d / 1450e | Chilled circulator required